Glassco Begins with clarity logo
Contact us | Technical Support
INQUIRY HOTLINE
Glassco & Danlogitech Global Series

Laboratory Heating Mantles & Extraction Units

The complete Glassco range for distillation, reflux, and Soxhlet extraction. Microprocessor PID control, glass fibre yarn insulation, and CE-certified safety. 100 ml – 20,000 ml.

STANDARD MANTLES

Hot spots causing flask breakage and sample degradation.

VS

GLASSCO PRECISION

360° soft-touch uniform heating with ±1°C PID stability.

DIRECT FACTORY QUOTE

B2B, OEM & Institutional Bulk Inquiries Only
READY FOR EXPORT • NABL COMPLIANT • OEM MANUFACTURER

COMPREHENSIVE PRODUCT SERIES

Explore the complete 2026 Danlogitech by Glassco’s Heating Mantle portfolio.
Engineered for durability, thermal stability, and operator safety.

Standard Analog series (1)

Analogue Heating Mantle — BlackDiamond™

Reliable, cost-effective heating for routine lab applications. Glass fibre yarn knitted mantle, analogue energy regulator, spill-collect system. DIN 12347 compliant. 100 ml – 20,000 ml.

  • 100ml to 20,000ml
  • Max Temp ~400°C
  • PU Coated SS & Aluminium Body
BEST SELLER

Digital Heating Mantle — BlackDiamond™ Pro

Microprocessor-controlled with LED display and external PT100 probe for direct liquid temperature control. Mantle/probe selection. Glass fibre insulation saves power wastage. 100 ml – 5,000 ml.

  • PID Temperature Controller
  • Accuracy ±1°C
  • External Probe (PT-100)

Heating Mantle with Stirrer — BlackDiamond™

Integrated magnetic stirrer with electronic speed control up to ~800 RPM. Independent heat and stir controls. Available in analogue (1223) and digital with probe (1221) variants. 100 ml – 5,000 ml.

  • Stirrer speed up to ~800 RPM
  • Electronic speed control
  • 100ml – 5,000ml capacity

Multi-Position Combined Units

Purpose-built for Soxhlet extraction and multiple simultaneous distillations. Available in 3-position and 6-position configurations. Flask capacity 100 ml – 500 ml per position. Mild steel body.

  • 100ml – 500ml per position
  • Individual control per position
  • 3-position & 6-position configs

Our Portfolio

1220 DNEU
200–1850W
1222 DNEU
200–650W
1223 DNEU
220–670W
1221 DNEU
220–670W
1225 DNEU
200–670W
HOLDING CAPACITY20,000 ml5000 ml5000 ml5000 ml5000 ml
STIR 800 RPM
DISPLAY1 LED1 LEDHEAT | STIR | TIME (3 LED)
TIMER
KNOBHEATHEATHEAT & STIRHEAT & STIRTOGGLE HEAT / STIR / TIME
INBUILT PROBE
MANTLE / PROBE
CELSIUS / FAHRENHEIT
PT100 SENSOR

Benchmarking Table: Analog vs. PID Digital

ParameterAnalog SeriesDigital (Danlogitech)
Housing MaterialPU-coated SS & AluminiumPU-coated SS & Aluminium
Heating ElementGlass fibre yarn mantleGlass fibre yarn mantle
Temp RangeAmbient to 400°CAmbient to ~400°C
Control LogicAnalog Energy RegulatorMicroprocessor PID
Safety FeaturesInternal GroundingFuse + Software Protection

Why Dan Logitech?

Glassco: Structural Excellence

Woven Glass Fiber ensures no direct element-to-flask contact, preventing thermal shock. Chemical-resistant powder coating protects the housing against corrosive spills.

Dan logitech: Intelligent Control

Proprietary PID algorithms eliminate overshoot. Dual-display monitoring (Set Value vs Process Value) ensures your reaction stays within safety parameters.

Reliability Testing

Every unit undergoes a 48-hour burn-in test. CE and ISO certifications come standard for all global laboratory compliance requirements.

Exporting Innovation

NABL, ISO, and CE certified instruments for pharmaceutical R&D, chemical synthesis, and petroleum testing worldwide.

CORE LABORATORY APPLICATIONS

Distillation & Fractionation

Essential for separating components based on volatility. Our mantles provide the uniform heating necessary to maintain a constant boiling point, crucial for high-purity fractionation.

Reflux Reactions

For organic synthesis requiring long-term heating without solvent loss. The PID controllers prevent thermal runaway, ensuring stable reflux conditions for hours or days.

Soxhlet Extraction

Widely used in food science and environmental testing. Our multi-position 'Extraction Banks' are specifically designed to house Soxhlet apparatus with dedicated control for each flask.

Vacuum Distillation

Heating heat-sensitive compounds at lower pressures. The precise voltage regulation of our analog series allows for the delicate 'nudging' of temperatures required under vacuum.

Technical Comparison Matrix

Standard Specifications for Glassco/Danlogitech Production Series

Export Full Spec Sheet
Flask CapacityAnalogue 1220 (W)Digital 1222 (W)With Stirrer 1221/1223 (W)Temp RangeController TypeApplication
100 ml200 W200 W220 WAmb. to ~400°CAnalogue / Digital PIDMicrochemistry
250 ml200 W200 W220 WAmb. to ~400°CAnalogue / Digital PIDStandard Distillation
500 ml250 W250 W270 WAmb. to ~400°CAnalogue / Digital PIDStandard Distillation
1,000 ml350 W350 W370 WAmb. to ~400°CAnalogue / Digital PIDReflux Reactions
2,000 ml500 W500 W520 WAmb. to ~400°CDigital PID with StirringOrganic Synthesis
3,000 ml500 W500 W520 WAmb. to ~400°CDigital PID with StirringSoxhlet Extraction
5,000 ml650 W650 W670 WAmb. to ~400°CDigital MicroprocessorPilot Plant Extraction
10,000 ml1,250 W——Amb. to ~400°CAnalogue (1220 series only)Bulk Production
20,000 ml1,850 W——Amb. to ~400°CAnalogue (1220 series only)Bulk Production

Note: Digital (1222) and Stirrer (1221/1223) series available up to 5,000 ml only. Customised wattages and multi-position bank configurations (3-position, 6-position) manufactured on request. All sizes 100–5,000 ml comply with DIN 12347.

Why Glassco Power Elements Outperform Competitors

At the heart of every Danlogitech heating mantle is our glass fibre yarn knitted mantle that ensures uniform, contact-free heating of the flask. The woven glass fibre acts as a thermal buffer — eliminating hot spots and preventing the thermal shock that causes flask breakage and sample degradation.
Safety is built into every BlackDiamond series mantle. The patented spill-collect system contains spillage from flask breakage up to 5 L within the mantle body. The PRO series (1225) adds dual PT sensors that independently cross-check temperature readings — triggering safe shutdown if either sensor reads an anomaly.

Internal Earthing

Integrated grounding throughout the element net and housing prevents electrical surges in case of liquid spillages or flask breakage.

PID Intelligence

Our microprocessor controllers utilize auto-tuning PID algorithms to eliminate temperature overshoot, protecting sensitive samples.

OEM & Distributor Benefits

Private Labeling

Full white-label manufacturing including customized housing colors and branding.

Inventory Priority

Tier-1 distributors get dedicated production queue slots for 24-hour dispatch.

Technical Documentation

NABL, CE, and ISO certificates provided for all local regulatory compliance.

TECHNICAL FAQ

The industrial analogue series (1220 — 10,000 ml and 20,000 ml) is rated for continuous operation. For long-term programmable cycles in smaller sizes, the Advanced Digital PRO (1225) with its timer and dual-sensor safety system is the recommended choice. The timer can be set from 1 min to 99:59 min with automatic shutoff.

No. All heating mantles are designed strictly for Round Bottom (RB) Flasks conforming to DIN 12347 to ensure proper surface contact.

For flat-bottom glassware, please enquire about DAN Logitech Hotplates (series 500B, 900) or the Digital Dry Block Heater (series 740/750).

The patented spill-collect system on all BlackDiamond series mantles is designed to contain spillage from flask breakage up to 5 L within the mantle body. The glass fibre heating net is chemically inert to most organic solvents. Switch off power immediately and dry-clean before reuse.

All stirrer-equipped heating mantles (series 1221, 1223, 1225) provide a maximum of ~800 RPM variable electronic stir control. The PRO series (1225) offers step control in 50 RPM increments from 50–800 RPM. Note: standalone DAN Logitech hotplate stirrers (series 500B, 900) reach up to 2,000 RPM — these are different products.

All BlackDiamond series are available in both 230V/50Hz (DNEU item codes — Europe, India, Middle East) and 115V/60Hz (DNUS item codes — USA, Americas, Japan). Both are production-standard. Specify voltage when placing an order. Example: 1222.DNEU.04 (1000 ml, 230V) vs 1222.DNUS.04 (1000 ml, 115V).

TRUSTED BY 5,000+ LABS WORLDWIDE

Ready to upgrade your laboratory heating instrumentation?

A global leader in laboratory glassware and instrumentation. Partnering with Danlogitech to deliver high-precision heating solutions to the pharmaceutical, academic, and industrial sectors.

Series Links

Documentation

Chat on WhatsApp